The tape isn't hard to replace. Just remove the
sponge bar. This takes the pressure off of the needles. Pull out the old needle position tape. It's usually is easier to pull it out towards the side of the machine. This is a good time to brush out any lint from the needle area. Clean out any old
oil too. Put a few drops of oil along the metal to help the tape adhear. This prevents the tape from shifting under the needles.
Take the new 4.5 Standard Gauge needle position tape and, starting at one end, push the end of the tape along under the needles. You may have to lift it slightly when it goes over the screw heads in the bed. Make sure the tape is centered correctly. There is a dotted line on the middle of either tape that fits between the two middle needles. Replace the
sponge bar. You're done. Your new needle position tape is ready to go to work.